APIC INSULATION TECHNICAL INFO

PROPERTIES
K-values
NOMINAL THICKNESSES mm 25 50 50 75 100 100
in. 1 2 2 3 4 4
NOMINAL DENSITY kg/m3 16 12 16 10 10 16
lbs/ft3 1.0 0.75 1.0 0.625 0.625 1.0
THERMAL CONDUCTIVITY K-VALUE W/mk 0.037 0.039 0.037 0.045 0.045 0.037
 Btu.ft2hoF/in 0.260 0.270 0.260 0.310 0.310 0.260
THERMAL RESISTANCE R-VALUE m2K/W 0.676 1.28 1.35 1.67 2.22 2.70
hft2oF/Btu 4.0 7.0 8.0 10.0 13.0 15.0
Based on 20oC(68oF) mean temperature
Alkalinity
ph9, Slightly Alkaline (ph7 is Neutral) when tested in accordance with British Standard 3958

Sound Absorption 
APIC Building Blankets reduce external noise such as rain or hail drumming, more so, if they are installed tight against the underside of the roofing material.  This creates a more pleasant internal environment within the structure.

 

FREQUENCY (hz)

THICKNESS

125

250

550

1000

2000

BB-25 mm (1 in) 0.11 0.22 0.34 0.50 0.63
BB-50 mm (2 in) 0.08 0.30 0.40 0.50 0.90
BB-75 mm (3 in.) 0.14 0.45 0.71 0.82 0.92

Moisture Absorption  
When a dry specimen is placed in conditions of 95 percent relative humidity at 50°C (120°F) for 96 hours.  Moisture absorption is less than 0.2 percent by volume.

The Rating Performance  
Unfaced Building Blankets are non-combustible and non-flammable as defined by combustibility test of AS A30, 1958, Sec. 1 conducted by commonwealth experimental Building station, North ryde, NSW and UL Classification Marking not exceeding FHC 25/50 November 6, 1986.

Early Fire Hazard Test
APIC GLASSWOOL products are tested in accordance with B.S. 476 Parts 5, b and 7 with Class "O" Fire Rating under the Building regulations Section E 15.

Early Fire Hazard Test in accordance with Australian Standard 1530 part 3-1982 and Underwriters Laboratories, Inc. (UL 723, ASTM E - 84) Sixth Edition.

 Burning Characteristics

AS

UL

 Ignitability Index

0

-

 Heat Evolved Index

0

-

 Spread of flame Index

0

15/0

 Smoked Developed Index

0-1

0

Comprehensive Strength
APIC Insualation has  excellent resilience.  It will cover to its nominal thickness after prolonged compression.   

 
Thermal Resistance

Thermal Resistance (R) Value Required

R Value

Thickness

R 4 25 mm
R 7 50 mm
R 8 50 mm
R 10 75 mm
R 13 100 mm
R 15 100 mm
 
Type of Vapour Barrier
When required, vapour barriers can be either adhered or rolled-in loosely with APIC BUILDING BLANKETS.  Recommended vapour barrier is the Foil Skrim Kraft (FSK), a lightweight single-sided, fire-rated aluminum foil bonded by polyethelene to a heavy duty Kraft laminating paper with glass fibre reinforcements. back to top   